Lightning Surge Suppressor – Series 5330

SKU: 5330 Category:

The Lightning Surge Suppressors – Series 5330 are two pair (four wire) modules implementing three-stage hybrid technology. These Lightning Surge Suppressors are intended for indoor use on communication loop circuits which have been isolated from a switch telephone network.

FEATURES:

  • Lightning Protection for Low Voltage Data Signal Lines
  • Plug-in Module
  • Three-Stage Protection
  • Sneak/Fault Current Protection
  • UL 497A Listed

The Lightning Surge Suppressors – Series 5330 are two pair (four wire) modules implementing three-stage hybrid technology. These Lightning Surge Suppressors are intended for indoor use on communication loop circuits which have been isolated from a switch telephone network. The Lightning Surge Suppressor addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated by the Lightning Surge Suppressor with resettable positive temperature coefficient fuses (PTCs). The Lightning Surge Suppressor’s PTCs increase resistance several orders of magnitude when over currents exceed safe levels. A normal state resumes when over currents are removed from the Lightning Surge Suppressor. The ability to self restore in this manner significantly increases the Lightning Surge Suppressor’s performance and survivability. Troubleshooting the Lightning Surge Suppressor – Model 5330 is easily performed by unplugging and plugging in a spare to check.

The Lightning Surge Suppressor’s card edge module is gold-plated, double sided and designed to mate with the gold-plated female terminal connector. When snapped together the data circuits “pass thru” the Lightning Surge Suppressor in a serial fashion from the four “Field Side” terminals to the four “Electronics Side” terminals. Terminals 1 or 10 of the Lightning Surge Suppressor must be attached to Building-Approved ground (preferably AC power safety ground).

Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 mA continuously. Do not daisy chain grounds. The Lightning Surge Suppressor is not intended for shield termination.

Specifications

Peak Surge Current 10 kA (8x 20 µs)
Clamping Voltage 8, 36, or 43 VDC
Maximum Operating Voltage 5, 30, or 36 VDC
Operating Current 150 mA
Frequency Range 0 to 20 MHz
Insertion Loss
Surge Suppressor Technology GDT, SAD, w/Series PTC
Connection Type Terminal block w/compression lugs (accepts up to 10 AWG)
Operating Temperature -40° to 185° F (-40° to 85° C)
Dimensions 2 x 1x 2.5 in (5.1 x 2.5 x 6.4 cm)(HxWxD)
Weight 1 oz (30 g)
Certifications UL 497A

Ordering Guide

 

Model 5330-01 Surge Suppressor with 8 Volt Clamp
Model 5330-05 Surge Suppressor with 36 Volt Clamp
Model 5330-06 Surge Suppressor with 43 Volt Clamp
Model 5330-09 Surge Suppressor, top only, (Specify Volt Clamp)
Model 5330-10 Surge Suppressor, base only

 

 

Support